
STC-A33A
2. Pulse Width Trigger Mode (Non-Reset, External Sync)
Note 1: The camera does NOT switch to the normal mode when the long exposure mode is selected. This timing chart
shows when the long exposure mode is selected.
Note 2: The internal VD signal is reset immediately after the exposure is finished. The video output signal is sent out
according to that reset VD timing.
Note 3: The exposure time is controlled by the pulse width of the trigger signal.
Note 4: External VD signal inputs continuously during the external sync mode. External VD signal is disregarded during
the trigger mode.
Note 5: The WEN signal does not output when the exposure by the trigger signal does not exist.
Normal mode
Exposure time
1H
Trigger mode Normal mode
Not e 1: Automatical ly sw i tches
to nor mal m ode if the pulse
width of the trigger si gnal is
mor e than 500 msec .
Function mode
External VD
CCD exposure
Trigger signal
(Positive)
Video out
Note 3
WEN signal out
Note 4
Note 5
Note 2
Application Manual 14 of 60 Rev1.0
Comentarios a estos manuales