SenTech STC-A33A Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
STC-A33A
Command No.
Command Descriptions
74H:
DSW_ST[9…8]
75H:
DSW_ST[7…0]
[Status of the DIP switch on the rear panel]
This obtains the status of the DIP switch on the rear panel.
D[9…0]
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D9:
Binning mode
0: ON (Binning)
1: OFF (Normal)
D8:
Sync system
0: HD/ VD signals in (External)
1: HD/VD signals out (Internal)
D7 to D6:
Scanning mode
00: 1/4 partial scanning
01: 1/2 partial scanning
10 to 11: Full scanning
D5:
Trigger polarity
0: Negative
1: Positive
D4 to D3:
Reset mode
10: V-Reset
11: Non-Reset
D2 to D0:
Shutter speed
000: 1/20,000 seconds
001: 1/8000 seconds
010: 1/4,000 seconds
011: 1/2000 seconds
100: 1/1000 seconds
101: 1/500 seconds
110: 1/200 seconds
111: Shutter off, pulse width trigger
7EH:
FWVR[15…8]
7FH:
FWVR[7…0]
[Firmware version verification] Initial data: FWVR[15..0] = Firmware version
This is used for the firmware version verification when the camera is powered on.
The data of the address 10H to 7FH on the EEPROM are initialized with the factory default if this and the value
on the register are not equal.
80H:
E2P[7…0]
[EEPROM control] Initial data: E2P[7…0] = 0
This sets the EEPROM control mode.
D[7…0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D2:
No function
Always set “000000”
D1:
Register simultaneously updates with the EEPROM
0: Prohibited
1: Permitted
D0:
Writing control into EEPROM
0: Prohibited
1: Permitted
Note 1: This bit is cleared to 0 automatically by the internal process after the execution of the
command
Note 2: By synchronizing to the EEPROM read/write access, the subject control register is also
updated.
Application Manual 28 of 60 Rev1.0
Vista de pagina 31