STC-A33A
3. Pulse Width Trigger Mode (Non-Reset, Internal Sync)
Note 1: The camera does NOT switch to the normal mode when the long exposure mode is selected. This timing chart
shows when the long exposure mode is selected.
Note 2: The internal VD signal does not reset by the trigger signal. The video output signal is sent out at the next VD
timing.
Note 3: The exposure time is controlled by the pulse width of the trigger signal.
Note 4: The external VD signal inputs continuously during the external sync mode.
Note 5: The WEN signal does not output when the exposure by the trigger signal does not exist.
4. Pulse Width Trigger Mode (Exposure Timing)
Note 1: The trigger signal that is less than or equal to 30 clocks is removed by the filtering system.
Note 2: The Input trigger signal has to be more than 31 clocks pulse width.
Note 3: The exposure starts 63 clocks after the rising edge of the trigger signal.
Normal mode
Exoposure time
Trigger mode Normal mode
Autom atically sw itches to
normal mode if the pul se width
of the trigger signal is m ore
than 500 msec .
Note. 1
Function mode
Internal VD
CCD exposure
Trigger signal
(Positive)
Video out
Note. 3
WEN signal out
Note. 5
Next
VD
Note. 2
Next
VD
Note. 4
T1'
SUB
SG
(127 CLK)
Trigger
singal
Exposure
time
Exposure time: T1' = T1 + 127 CLK
T1
30 CLK
Filtering (Note.1)
Application Manual 15 of 60 Rev1.0